product overview
EN series large ceiling-type air cooler is mainly fitted with large-size fans motors with a diameter above 710mm to meet the requirements of high cooling capacity or large cold storage.This series of products has the following characteristics:
Casing:High-quality galvanized steel plate sprayed with powder coating (silver gray RA19006),with desirable corrosion resistance;both the side plates and the outer water tray plate are designed with hinged structure, which is convenient to operate;
The side sheet of the heat exchanger is supported by aluminum plate to prevent the copper tube from contacting the steel plate and effectively protect the copper tube;
Double drain trays design: The outer water tray is designed with edge structure with angle, which makes the water drain smoothly without any dead angle; the inner water tray is designed with sink structure made of aluminum plate, and the condensed water or defrost water is directly discharged into the drainage outlet of the outer water tray through the inner water tray;
There are floor supports for easy installation;
Coil:φ15 copper tubes with a square arrangement,low heat transfer temperature difference,low dry food consumption and slow frosting speed of fins;
Corrugated aluminum sheet made of hydrophilic aluminum foil, with the sheet spacing of 4.0mm, 6.0mm, 9.0mm and 12.0mm to meet the requirements of different temperatures and humidity;
Fan: 6-pole external rotor fan with large diameter; fan specifications: φ710, φ800 and φ910,product series of different specifications,giving users more choices;
Defrosting:The electric defrosting is adopted in the standard manner,and the stainless steel heating tubes are distributed in the coil fins and inner water plates plates,which can bring about desirable defrosting effect; the steam defrosting can be adopted as required by the customer.
The IP65 waterproof junction box and waterproof connectors are used, with better waterproofing; the fan and the heating pipe are wired separately, which can lead to high reliability;
The outlet of the air cooler is equipped with a needle valve, which is convenient for users to test the pressure;
It is subjected to strict pressure test at the pressure of 23bar;
The expansion valves, heating band of fan tube and wind deflector can be pre-installed according to customer's needs;
It is compatible with R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.
Model Description
Standard and Optianal Commponents
component | Configutation | component | Configutation | ||
Casing | Powder coated aluminum-magnesium plate | × | Defrost | Air defrost | ○ |
Powder coated steel plate | ○ | Electric heating pipe | ● | ||
Powder coated galvanized sheet | ● | Hot gas defrost (coil & tray) | ○ | ||
Stainless steel plate | ○ | Expansion valve | ○ | ||
Motor | Weiguang external rotor motor | ● | Drain heater | ○ | |
EBM external rotor motor | ○ | Fan tube heat | ○ | ||
Aluminum foil | Normal aluminium foil | ○ | |||
Hydrophilic aluminum foil (blue foil) | ● | ||||
●:Standard component;○:Optional component;×:Not available |
Performance Datasheet
Model | Cooling capacity/R404A(KW) | Surface | Tube volume |
Airflow | Air throw | Connetion pipe(mm) | Weight | ||||||
Tc=0℃ | Tc=10℃ | m2 | dm3 | m3/h | m | Liquid inlet |
Gas outlet |
Drain | kg | ||||
ΔΤ=8K | ΔΤ=10K | ||||||||||||
710 fan series | |||||||||||||
EN711/DL-ET | 20.4 | 30 | 136 | 19.5 | 11800 | 30 | 22 | 35 | R2" | 210 | |||
EN711/EL-ET | 22.9 | 33.2 | 170 | 24.4 | 11200 | 30 | 22 | 35 | R2" | 222 | |||
EN711/FL-ET | 25.5 | 37.5 | 204 | 29.3 | 10800 | 29 | 28 | 35 | R2" | 234 | |||
EN711/HL-ET | 28.5 | 41.9 | 272 | 39 | 10000 | 28 | 28 | 42 | R2" | 258 | |||
EN712/DL-ET | 40.8 | 60 | 272 | 37.7 | 23600 | 33 | 35 | 42 | R2" | 358 | |||
EN712/EL-ET | 45.9 | 67.5 | 340 | 47.2 | 22400 | 33 | 35 | 54 | R2" | 379 | |||
EN712/FL-ET | 51 | 75 | 408 | 56.6 | 21600 | 32 | 35 | 54 | R2" | 406 | |||
EN712/HL-ET | 57.1 | 83.9 | 544 | 75.5 | 20000 | 31 | 35 | 54 | R2" | 453 | |||
EN713/DL-ET | 61.2 | 90 | 408 | 56 | 35400 | 35 | 35 | 54 | R2" | 506 | |||
EN713/EL-ET | 66.2 | 97.3 | 490 | 67.2 | 33600 | 35 | 35 | 54 | R2" | 540 | |||
EN713/FL-ET | 76.5 | 112.4 | 612 | 84 | 32400 | 34 | 35 | 67 | R2" | 577 | |||
EN713/HL-ET | 85.7 | 126 | 817 | 112 | 30000 | 33 | 35 | 67 | R2" | 646 | |||
800 fan series | |||||||||||||
EN801/DL-ET | 28.1 | 41.3 | 187 | 26.5 | 17300 | 35 | 28 | 42 | R2" | 252 | |||
EN801/EL-ET | 31.5 | 46.3 | 233 | 33.2 | 16500 | 35 | 28 | 42 | R2" | 268 | |||
EN801/FL-ET | 35 | 51.4 | 280 | 39.8 | 15800 | 34 | 28 | 42 | R2" | 284 | |||
EN801/HL-ET | 39.2 | 57.6 | 373 | 53.1 | 15100 | 33 | 35 | 54 | R2" | 317 | |||
EN802/DL-ET | 56 | 82.3 | 373 | 51.6 | 34600 | 38 | 35 | 54 | R2" | 431 | |||
EN802/EL-ET | 63 | 92.6 | 467 | 64.4 | 33000 | 38 | 35 | 54 | R2" | 464 | |||
EN802/FL-ET | 70 | 102.9 | 560 | 77.4 | 31600 | 37 | 35 | 67 | R2" | 497 | |||
EN802/HL-ET | 78.4 | 115.2 | 747 | 103.1 | 30200 | 36 | 35 | 67 | R2" | 562 | |||
EN803/DL-ET | 84 | 123.5 | 560 | 76.6 | 51900 | 40 | 35 | 67 | R2" | 614 | |||
EN803/EL-ET | 94.5 | 138.9 | 700 | 95.7 | 49500 | 40 | 2-35 | 2-54 | R2" | 664 | |||
EN803/FL-ET | 105 | 154.4 | 840 | 114.8 | 47400 | 39 | 2-35 | 2-54 | R2" | 711 | |||
EN803/HL-ET | 117.6 | 172.8 | 1120 | 153.1 | 45300 | 38 | 2-35 | 2-54 | R2" | 815 | |||
910 fan series | |||||||||||||
EN911/DL-ET | 37.4 | 55 | 249 | 35.4 | 23100 | 40 | 35 | 42 | R2" | 305 | |||
EN911/EL-ET | 42 | 61.7 | 311 | 44.3 | 22100 | 40 | 35 | 54 | R2" | 327 | |||
EN911/FL-ET | 46.6 | 68.5 | 373 | 53.1 | 20800 | 39 | 35 | 54 | R2" | 349 | |||
EN911/HL-ET | 52.3 | 76.9 | 498 | 70.8 | 20000 | 38 | 35 | 54 | R2" | 392 | |||
EN912/DL-ET | 74.7 | 109.8 | 498 | 68.7 | 46200 | 44 | 35 | 67 | R2" | 521 | |||
EN912/EL-ET | 84 | 123.5 | 622 | 85.9 | 44200 | 44 | 35 | 67 | R2" | 565 | |||
EN912/FL-ET | 93.4 | 137.3 | 747 | 103.1 | 41600 | 43 | 2-35 | 2-54 | R2" | 608 | |||
EN912/HL-ET | 104.5 | 153.6 | 995 | 137.5 | 40000 | 42 | 2-35 | 2-54 | R2" | 694 | |||
EN913/DL-ET | 112.1 | 164.8 | 747 | 102.1 | 69300 | 47 | 2-35 | 2-54 | R2" | 742 | |||
EN913/EL-ET | 122.9 | 180.7 | 910 | 127.6 | 66300 | 47 | 2-35 | 2-67 | R2" | 808 | |||
EN913/FL-ET | 140 | 205.8 | 1120 | 153.1 | 62400 | 46 | 2-35 | 2-67 | R2" | 873 | |||
EN913/HL-ET | 156.8 | 230.5 | 1493 | 204.1 | 60000 | 45 | 2-35 | 2-67 | R2" | 1007 | |||
1)Tc in the table is the cold room temperature; ΔΤ is the heat transfer temperature difference,that is,the difference between the cold room temperature and the evaporation temperature. 2) The air throw is 0.5m/s at ambient temperature. 3) For the cooling capacity in other working conditions, refer to the correction coefficient. |
|||||||||||||
Fin pitch6.0mm | |||||||||||||
Model | Cooling capacity/R404A(KW) | Surface | Tube volume |
Airflow | Air throw | Connetion pipe(mm) | Weight | ||||||
Tc=0℃ | Tc=-18℃ | m2 | dm3 | m3/h | m | Liquid inlet |
Gas outlet |
Drain | kg | ||||
ΔΤ=8K | ΔΤ=7K | ||||||||||||
710 fan series | |||||||||||||
EN711/DD-ET | 16.5 | 13.2 | 92 | 19.5 | 12800 | 30 | 22 | 35 | R2" | 200 | |||
EN711/ED-ET | 19.5 | 15.6 | 115 | 24.4 | 12300 | 30 | 22 | 35 | R2" | 210 | |||
EN711/FD-ET | 22 | 17.5 | 138 | 29.3 | 11800 | 29 | 28 | 35 | R2" | 220 | |||
EN711/HD-ET | 26.8 | 21.4 | 185 | 39 | 11200 | 28 | 28 | 42 | R2" | 239 | |||
EN712/DD-ET | 33.3 | 26.5 | 185 | 37.7 | 25600 | 33 | 35 | 42 | R2" | 337 | |||
EN712/ED-ET | 39.2 | 31.3 | 231 | 47.2 | 24600 | 33 | 35 | 54 | R2" | 356 | |||
EN712/FD-ET | 44.3 | 35.4 | 277 | 56.6 | 23600 | 32 | 35 | 54 | R2" | 378 | |||
EN712/HD-ET | 53.5 | 42.8 | 369 | 75.5 | 22400 | 31 | 35 | 54 | R2" | 415 | |||
EN713/DD-ET | 49.8 | 39.8 | 277 | 56 | 38400 | 35 | 35 | 54 | R2" | 477 | |||
EN713/ED-ET | 56.4 | 45 | 332 | 67.2 | 36900 | 35 | 35 | 54 | R2" | 505 | |||
EN713/FD-ET | 66.4 | 53 | 415 | 84 | 35400 | 34 | 35 | 67 | R2" | 534 | |||
EN713/HD-ET | 80.3 | 64.2 | 554 | 112 | 33600 | 33 | 35 | 67 | R2" | 589 | |||
800 fan series | |||||||||||||
EN801/DD-ET | 22.9 | 18.3 | 127 | 26.5 | 18800 | 36 | 28 | 42 | R2" | 239 | |||
EN801/ED-ET | 26.9 | 21.5 | 158 | 33.2 | 18000 | 36 | 28 | 42 | R2" | 252 | |||
EN801/FD-ET | 30.4 | 24.3 | 190 | 39.8 | 17300 | 35 | 28 | 42 | R2" | 265 | |||
EN801/HD-ET | 36.7 | 29.4 | 253 | 53.1 | 16500 | 34 | 35 | 54 | R2" | 291 | |||
EN802/DD-ET | 45.5 | 36.4 | 253 | 51.6 | 37600 | 39 | 35 | 54 | R2" | 405 | |||
EN802/ED-ET | 53.7 | 43 | 316 | 64.4 | 36000 | 39 | 35 | 54 | R2" | 432 | |||
EN802/FD-ET | 60.8 | 48.6 | 380 | 77.4 | 34600 | 38 | 35 | 67 | R2" | 458 | |||
EN802/HD-ET | 73.4 | 58.7 | 506 | 103.1 | 33000 | 37 | 35 | 67 | R2" | 510 | |||
EN803/DD-ET | 68.4 | 54.7 | 380 | 76.6 | 56400 | 41 | 35 | 67 | R2" | 576 | |||
EN803/ED-ET | 80.8 | 64.6 | 475 | 95.7 | 54000 | 41 | 2-35 | 2-54 | R2" | 615 | |||
EN803/FD-ET | 91.2 | 73 | 570 | 114.8 | 51900 | 40 | 2-35 | 2-54 | R2" | 653 | |||
EN803/HD-ET | 110.2 | 88.2 | 760 | 153.1 | 49500 | 39 | 2-35 | 2-54 | R2" | 737 | |||
910 fan series | |||||||||||||
EN911/DD-ET | 30.4 | 24.3 | 169 | 35.4 | 25000 | 41 | 35 | 42 | R2" | 288 | |||
EN911/ED-ET | 35.9 | 28.7 | 211 | 44.3 | 24100 | 41 | 35 | 54 | R2" | 305 | |||
EN911/FD-ET | 40.5 | 32.4 | 253 | 53.1 | 23100 | 40 | 35 | 54 | R2" | 323 | |||
EN911/HD-ET | 49 | 39.2 | 338 | 70.8 | 22100 | 39 | 35 | 54 | R2" | 357 | |||
EN912/DD-ET | 60.8 | 48.6 | 338 | 68.7 | 50000 | 45 | 35 | 67 | R2" | 486 | |||
EN912/ED-ET | 71.7 | 57.4 | 422 | 85.9 | 48200 | 45 | 35 | 67 | R2" | 522 | |||
EN912/FD-ET | 81 | 64.8 | 506 | 103.1 | 46200 | 44 | 2-35 | 2-54 | R2" | 556 | |||
EN912/HD-ET | 97.9 | 78.3 | 675 | 137.5 | 44200 | 43 | 2-35 | 2-54 | R2" | 624 | |||
EN913/DD-ET | 91.1 | 72.9 | 506 | 102.1 | 75000 | 48 | 2-35 | 2-54 | R2" | 690 | |||
EN913/ED-ET | 104.9 | 83.9 | 617 | 127.6 | 72300 | 48 | 2-35 | 2-67 | R2" | 743 | |||
EN913/FD-ET | 121.6 | 97.3 | 760 | 153.1 | 69300 | 47 | 2-35 | 2-67 | R2" | 795 | |||
EN913/HD-ET | 146.9 | 117.5 | 1013 | 204.1 | 66300 | 46 | 2-35 | 2-67 | R2" | 903 | |||
1)Tc in the table is the cold room temperature; ΔΤ is the heat transfer temperature difference,that is,the difference between the cold room temperature and the evaporation temperature. 2) The air throw is 0.5m/s at ambient temperature. 3) For the cooling capacity in other working conditions, refer to the correction coefficient. |
|||||||||||||
Fin pitch9.0mm | |||||||||||||
Model | Cooling capacity/R404A(KW) | Surface | Tube volume |
Airflow | Air throw | Connetion pipe(mm) | Weight | ||||||
Tc=0℃ | Tc=-18℃ | Tc=-25℃ | m2 | dm3 | m3/h | m | Liquid inlet |
Gas outlet |
Drain | kg | |||
ΔΤ=8K | ΔΤ=7K | ΔΤ=6K | |||||||||||
710 fan series | |||||||||||||
EN711/FJ-ET | 19 | 15.2 | 12.5 | 95 | 29.3 | 12300 | 30 | 28 | 35 | R2" | 223 | ||
EN711/HJ-ET | 22.6 | 18 | 14.9 | 126 | 39 | 11800 | 29 | 28 | 42 | R2" | 243 | ||
EN712/FJ-ET | 39 | 31.2 | 25.7 | 190 | 56.6 | 24600 | 33 | 35 | 54 | R2" | 384 | ||
EN712/HJ-ET | 45.5 | 36.4 | 30 | 253 | 75.5 | 23600 | 32 | 35 | 54 | R2" | 423 | ||
EN713/FJ-ET | 56.8 | 45.4 | 37.5 | 284 | 84 | 36900 | 35 | 35 | 67 | R2" | 544 | ||
EN713/HJ-ET | 68.2 | 54.5 | 45 | 379 | 112 | 35400 | 34 | 35 | 67 | R2" | 602 | ||
800 fan series | |||||||||||||
EN801/FJ-ET | 26 | 20.8 | 17.2 | 130 | 39.8 | 18000 | 36 | 28 | 42 | R2" | 269 | ||
EN801/HJ-ET | 31.1 | 24.9 | 20.5 | 173 | 53.1 | 17300 | 35 | 35 | 54 | R2" | 297 | ||
EN802/FJ-ET | 52 | 41.6 | 34.3 | 260 | 77.4 | 36000 | 39 | 35 | 67 | R2" | 466 | ||
EN802/HJ-ET | 62.3 | 49.8 | 41.1 | 346 | 103.1 | 34600 | 38 | 35 | 67 | R2" | 522 | ||
EN803/FJ-ET | 78 | 62.4 | 51.5 | 390 | 114.8 | 54000 | 41 | 2-35 | 2-54 | R2" | 666 | ||
EN803/HJ-ET | 93.6 | 74.9 | 61.7 | 520 | 153.1 | 51900 | 40 | 2-35 | 2-54 | R2" | 755 | ||
910 fan series | |||||||||||||
EN911/FJ-ET | 34.6 | 27.7 | 22.8 | 173 | 53.1 | 24100 | 41 | 35 | 54 | R2" | 329 | ||
EN911/HJ-ET | 41.6 | 33.3 | 27.4 | 231 | 70.8 | 23100 | 40 | 35 | 54 | R2" | 365 | ||
EN912/FJ-ET | 69.2 | 55.4 | 45.6 | 346 | 103.1 | 48200 | 45 | 2-35 | 2-54 | R2" | 568 | ||
EN912/HJ-ET | 83.2 | 66.6 | 54.9 | 462 | 137.5 | 46200 | 44 | 2-35 | 2-54 | R2" | 640 | ||
EN913/FJ-ET | 104 | 83.2 | 68.6 | 520 | 153.1 | 72300 | 48 | 2-35 | 2-67 | R2" | 813 | ||
EN913/HJ-ET | 124.7 | 99.8 | 82.3 | 693 | 204.1 | 69300 | 47 | 2-35 | 2-67 | R2" | 926 | ||
1)Tc in the table is the cold room temperature; ΔΤ is the heat transfer temperature difference,that is,the difference between the cold room temperature and the evaporation temperature. 2) The air throw is 0.5m/s at ambient temperature. 3) For the cooling capacity in other working conditions, refer to the correction coefficient. |
|||||||||||||
Fin pitch12.0mm | |||||||||||||
Model | Cooling capacity/R404A(KW) | Surface | Tube volume |
Airflow | Air throw | Connetion pipe(mm) | Weight | ||||||
Tc=0℃ | Tc=-25℃ | Tc=-35℃ | m2 | dm3 | m3/h | m | Liquid inlet |
Gas outlet |
Drain | kg | |||
ΔΤ=8K | ΔΤ=7K | ΔΤ=6K | |||||||||||
710 fan series | |||||||||||||
EN711/FK-ET | 16.4 | 10.8 | 10.6 | 73 | 29.3 | 12800 | 30 | 28 | 35 | R2" | 215 | ||
EN711/HK-ET | 19.8 | 13 | 12.8 | 97 | 39 | 12300 | 29 | 28 | 42 | R2" | 233 | ||
EN712/FK-ET | 32.8 | 21.6 | 21.3 | 146 | 56.6 | 25600 | 33 | 35 | 54 | R2" | 368 | ||
EN712/HK-ET | 39.7 | 26.2 | 25.8 | 194 | 75.5 | 24600 | 32 | 35 | 54 | R2" | 402 | ||
EN713/FK-ET | 49.2 | 32.4 | 31.9 | 219 | 84 | 38400 | 35 | 35 | 67 | R2" | 520 | ||
EN713/HK-ET | 59.8 | 39.4 | 38.8 | 292 | 112 | 36900 | 34 | 35 | 67 | R2" | 571 | ||
800 fan series | |||||||||||||
EN801/FK-ET | 22.5 | 14.9 | 14.6 | 100 | 39.8 | 18800 | 36 | 28 | 42 | R2" | 259 | ||
EN801/HK-ET | 27.3 | 18 | 17.7 | 133 | 53.1 | 18000 | 35 | 35 | 54 | R2" | 282 | ||
EN802/FK-ET | 45 | 29.7 | 29.3 | 200 | 77.4 | 37600 | 39 | 35 | 67 | R2" | 445 | ||
EN802/HK-ET | 54.7 | 36.1 | 35.6 | 267 | 103.1 | 36000 | 38 | 35 | 67 | R2" | 493 | ||
EN803/FK-ET | 67.5 | 44.6 | 43.9 | 300 | 114.8 | 56400 | 41 | 2-35 | 2-54 | R2" | 634 | ||
EN803/HK-ET | 82 | 54.1 | 53.3 | 400 | 153.1 | 54000 | 40 | 2-35 | 2-54 | R2" | 711 | ||
910 fan series | |||||||||||||
EN911/FK-ET | 29.9 | 19.7 | 19.4 | 133 | 53.1 | 25000 | 41 | 35 | 54 | R2" | 315 | ||
EN911/HK-ET | 36.5 | 24.1 | 23.7 | 178 | 70.8 | 24100 | 40 | 35 | 54 | R2" | 346 | ||
EN912/FK-ET | 60.1 | 39.7 | 39.1 | 267 | 103.1 | 50000 | 45 | 2-35 | 2-54 | R2" | 539 | ||
EN912/HK-ET | 73 | 48.2 | 47.5 | 356 | 137.5 | 48200 | 44 | 2-35 | 2-54 | R2" | 601 | ||
EN913/FK-ET | 90 | 59.4 | 58.5 | 400 | 153.1 | 75000 | 48 | 2-35 | 2-67 | R2" | 769 | ||
EN913/HK-ET | 109.3 | 72.1 | 71 | 533 | 204.1 | 72300 | 47 | 2-35 | 2-67 | R2" | 869 | ||
1)Tc in the table is the cold room temperature; ΔΤ is the heat transfer temperature difference,that is,the difference between the cold room temperature and the evaporation temperature. 2) The air throw is 0.5m/s at ambient temperature. 3) For the cooling capacity in other working conditions, refer to the correction coefficient. |
Electrical Parameters
Model | Fan motor | Defrosting with electric heating | |||||
Voltage(V) | Power(W) | Current(A) | Rotation speed(r/min) | Coil(KW) | Water plate(KW) | Total power(KW) | |
EN711/D* | 380-3 | 1030 | 2.35 | 905 | 5×1.2 | 2×1.4 | 8.8 |
EN711/E* | 380-3 | 1030 | 2.35 | 905 | 6×1.2 | 2×1.4 | 10 |
EN711/F* | 380-3 | 1030 | 2.35 | 905 | 8×1.2 | 2×1.4 | 12.4 |
EN711/H* | 380-3 | 1030 | 2.35 | 905 | 10×1.2 | 2×1.4 | 14.8 |
EN712/D* | 380-3 | 2060 | 4.7 | 905 | 5×2.4 | 2×2.6 | 17.2 |
EN712/E* | 380-3 | 2060 | 4.7 | 905 | 6×2.4 | 2×2.6 | 19.6 |
EN712/F* | 380-3 | 2060 | 4.7 | 905 | 8×2.4 | 2×2.6 | 24.4 |
EN712/H* | 380-3 | 2060 | 4.7 | 905 | 10×2.4 | 2×2.6 | 29.2 |
EN713/D* | 380-3 | 3090 | 7.05 | 905 | 6×3.0 | 2×3.0 | 24 |
EN713/E* | 380-3 | 3090 | 7.05 | 905 | 7×3.0 | 2×3.0 | 27 |
EN713/F* | 380-3 | 3090 | 7.05 | 905 | 10×3.0 | 2×3.0 | 36 |
EN713/H* | 380-3 | 3090 | 7.05 | 905 | 12×3.0 | 2×3.0 | 42 |
EN801/D* | 380-3 | 1940 | 3.9 | 880 | 6×1.4 | 2×1.5 | 11.4 |
EN801/E* | 380-3 | 1940 | 3.9 | 880 | 8×1.4 | 2×1.6 | 14.4 |
EN801/F* | 380-3 | 1940 | 3.9 | 880 | 9×1.4 | 2×1.6 | 15.8 |
EN801/H* | 380-3 | 1940 | 3.9 | 880 | 12×1.4 | 2×1.6 | 20 |
EN802/D* | 380-3 | 3880 | 7.8 | 880 | 6×2.8 | 2×2.9 | 22.6 |
EN802/E* | 380-3 | 3880 | 7.8 | 880 | 8×2.8 | 2×2.9 | 28.2 |
EN802/F* | 380-3 | 3880 | 7.8 | 880 | 9×2.8 | 2×2.9 | 31 |
EN802/H* | 380-3 | 3880 | 7.8 | 880 | 12×2.8 | 2×2.9 | 39.4 |
EN803/D* | 380-3 | 5820 | 11.7 | 880 | 8×3.0 | 3×3.0 | 33 |
EN803/E* | 380-3 | 5820 | 11.7 | 880 | 11×3.0 | 3×3.0 | 42 |
EN803/F* | 380-3 | 5820 | 11.7 | 880 | 12×3.0 | 3×3.0 | 45 |
EN803/H* | 380-3 | 5820 | 11.7 | 880 | 18×3.0 | 3×3.0 | 63 |
EN911/D* | 380-3 | 2480 | 5.15 | 885 | 8×1.4 | 2×1.6 | 14.4 |
EN911/E* | 380-3 | 2480 | 5.15 | 885 | 10×1.4 | 2×1.6 | 17.2 |
EN911/F* | 380-3 | 2480 | 5.15 | 885 | 12×1.4 | 2×1.6 | 20 |
EN911/H* | 380-3 | 2480 | 5.15 | 885 | 16×1.4 | 2×1.6 | 25.6 |
EN912/D* | 380-3 | 4960 | 10.3 | 885 | 8×2.8 | 2×2.9 | 28.2 |
EN912/E* | 380-3 | 4960 | 10.3 | 885 | 10×2.8 | 2×2.9 | 33.8 |
EN912/F* | 380-3 | 4960 | 10.3 | 885 | 12×2.8 | 2×2.9 | 39.4 |
EN912/H* | 380-3 | 4960 | 10.3 | 885 | 16×2.8 | 2×2.9 | 50.6 |
EN913/D* | 380-3 | 7440 | 15.45 | 885 | 11×3.0 | 3×3.0 | 42 |
EN913/E* | 380-3 | 7440 | 15.45 | 885 | 14×3.0 | 3×3.0 | 51 |
EN913/F* | 380-3 | 7440 | 15.45 | 885 | 18×3.0 | 3×3.0 | 63 |
EN913/H* | 380-3 | 7440 | 15.45 | 885 | 21×3.0 | 3×3.0 | 72 |
Do you attend exhibition?
Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.
Why choose us
Professional:28 years focus one thing-refrigeration equipments
Material we use sufficient
Certificate:CE, ISO, and cetiifcate of producing special pressure equipment
Projects reference?
FAQ
1, Q:Where is your factory address?
A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.
2, Q: What is your package?
A: Our package comply to custom require not include original wood.
3, Q:What is your MOQ?
A: Ordinary products can order from 1 set.
4, Q: Can you offer sample?
A: Yes,we can offer sample.and cost and delivery at your charge.
5, Q:I can't find products on your list?
A: Please contact me directly.
6,Q:How can i confirm your factory?
A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.
문의 사항을 바로 보내주세요.